翻訳と辞書
Words near each other
・ Electronic cigarettes in Australia
・ Electronic circuit
・ Electronic circuit design
・ Electronic circuit simulation
・ Electronic civil disobedience
・ Electronic Classroom of Tomorrow
・ Electronic Colloquium on Computational Complexity
・ Electronic colonialism
・ Electronic color code
・ Electronic Commerce Code Management Association
・ Electronic Commerce Directive
・ Electronic Commerce Protection Act
・ Electronic Commerce Regulations 2002
・ Electronic common technical document
・ Electron capture
Electron capture detector
・ Electron capture ionization
・ Electron configuration
・ Electron configurations of the elements (data page)
・ Electron cooling
・ Electron counting
・ Electron crystallography
・ Electron cyclotron resonance
・ Electron deficiency
・ Electron degeneracy pressure
・ Electron density
・ Electron diffraction
・ Electron donor
・ Electron electric dipole moment
・ Electron energy loss spectroscopy


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Electron capture detector : ウィキペディア英語版
Electron capture detector

An electron capture detector (ECD) is a device for detecting atoms and molecules in a gas through the attachment of electrons via electron capture ionization. The device was invented in 1957 by James Lovelock and is used in gas chromatography to detect trace amounts of chemical compounds in a sample.
==Gas chromatograph detector==

The electron capture detector is used for detecting electron-absorbing components (high electronegativity) such as halogenated compounds in the output stream of a gas chromatograph. The ECD uses a radioactive beta particle (electron) emitter in conjunction with a so-called makeup gas flowing through the detector chamber. The electron emitter typically consists of a metal foil holding 10 millicuries (370 MBq) of the radionuclide . Usually, nitrogen is used as makeup gas, because it exhibits a low excitation energy, so it is easy to remove an electron from a nitrogen molecule. The electrons emitted from the electron emitter collide with the molecules of the makeup gas, resulting in many more free electrons. The electrons are accelerated towards a positively charged anode, generating a current. There is therefore always a background signal present in the chromatogram. As the sample is carried into the detector by the carrier gas, electron-absorbing analyte molecules capture electrons and thereby reduce the current between the collector anode and a cathode. The analyte concentration is thus proportional to the degree of electron capture. ECD detectors are particularly sensitive to halogens, organometallic compounds, nitriles, or nitro compounds.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Electron capture detector」の詳細全文を読む